 EMC filters
2-line filters
for converters in traction systems
Rated current 250 to 1000 A
Series/Type: Date: B84142A*S002 ... S018 January 2006
EPCOS AG 2006. Reproduction, publication and dissemination of this data sheet and the information contained therein without EPCOS' prior express consent is prohibited.
2-line filters for converters in traction systems
Power line filters for DC systems Rated voltage 750 to 2000 V DC Rated current 250 to 1000 A Construction
2-line filters Metal case
B84142A*S002 ... S018
Features
Easy to install
Space-saving design
Optimized for long motor cables
and operation under full load
Design based on
EN 133 200, UL 1283, CSA C22.2 No.8 Applications
Trams, light rails Subways
Terminals
Busbars, tin-plated
Marking Marking on component: Manufacturer's logo, ordering code, rated voltage, rated current, rated temperature, climatic category, date code Minimum marking on packaging: Manufacturer's logo, ordering code Typical circuit diagram
L+ L_ LINE
L+' L_ ' LOAD
Traction side
Converter
SSB1309-8-E
Please read Cautions and warnings and
Important notes at the end of this document.
2
01/06
2-line filters for converters in traction systems
Technical data and measuring conditions Rated voltage VR Type S002: 750 V DC Type S003: 1000 V DC Type S018: 2000 V DC
B84142A*S002 ... S018
Rated current IR Test voltage Vtest
Referred to 60 C ambient temperature Type S002: 2000 V DC, 60 s (L+/L-) 4900 V DC, 60 s (L+ || L-/case) 6000 V DC, 2 s (L+ || L-/case) Type S003: 2500 V DC, 60 s (L+/L-) 4900 V DC, 60 s (L+ || L-/case) 6000 V DC, 2 s (L+ || L-/case) Type S018: 4000 V DC, 60 s (L+/L-) 4900 V DC, 60 s (L+ || L-/case) 6000 V DC, 2 s (L+ || L-/case)
Overload capability (thermal) Climatic category (IEC 60068-1)
1.6 * IR for 20 s per hour or 2.0 * IR for 10 s per hour 40/100/21 (-40 C/+100 C/21 days damp heat test)
Characteristics and ordering codes VR DC V 750 IR A 250 500 1000 1000 250 500 1000 2000 250 500 1000 Rtyp 63 57 33 63 57 33 63 57 33 Approx. weight kg 12 13 26 12 13 26 12 13 26 Ordering code
B84142A0250S002 B84142A0500S002 B84142A1000S002 B84142A0250S003 B84142A0500S003 B84142A1000S003 B84142A0250S018 B84142A0500S018 B84142A1000S018
Please read Cautions and warnings and
Important notes at the end of this document.
3
01/06
2-line filters for converters in traction systems
Dimensional drawings B84142A0250S0** (250 A)
B84142A*S002 ... S018
140 1100.5 PE M10 x 30 o11 PE M10 x 30 30 2 x M6 x 6
25
36
5 401 15 3602
5 401 15
80
300 60 1200.5 1200.5 60
+
+
5
_
o12
LINE
LOAD
_
190
Marking
1651
SSB1587-R
Please read Cautions and warnings and
Important notes at the end of this document.
4
01/06
2
91
116
2-line filters for converters in traction systems
B84142A0500S0** (500 A)
B84142A*S002 ... S018
140 1100.5 PE M10 x 30 o11 PE M10 x 30 30 2 x M6 x 6
30
36
5 401 15 3602
5 401 15
80
300 60 1200.5 1200.5 60
+
+
5
_
o12
LINE
LOAD
_
190
Marking
1651
SSB1588-Z
Please read Cautions and warnings and
Important notes at the end of this document.
5
01/06
2
91
116
2-line filters for converters in traction systems
B84142A1000S0** (1000 A)
B84142A*S002 ... S018
210 o14 84.53 o14 84.53 1800.8 4 x M6 x 6
950.8 2
61
20 40 4102.5 40
20
PE
M6 x 25
80
350 60 2901 220 60
+
8
+ LINE o12 LOAD
_
_
260
Marking
2351
SSB1589-8
Please read Cautions and warnings and
Important notes at the end of this document.
6
01/06
16
126
40
2-line filters for converters in traction systems
Insertion loss (typical values at Z = 50 )
B84142A*S002 ... S018
unsymmetrical, adjacent branches terminated common mode, all branches in parallel (asymmetrical) differential mode (symmetrical) Filters for 250 and 500 A
100 dB 80
SSB1573-L
Filters for 1000 A
B84142A0250S0** B84142A0500S0**
100 dB 80
SSB1574-U
B84142A1000S002 B84142A1000S003 B84142A1000S018
60
60
40
40
20
20
0 10 4
10 5
10 6
10 7
Hz 10 8 f
04 10
10 5
10 6
10 7
Hz 10 8 f
Please read Cautions and warnings and
Important notes at the end of this document.
7
01/06
EMC filters Cautions and warnings
Important information Please read all safety and warning notes carefully before installing the EMC filter and putting it into ). The same applies to the warning signs on the filter. Please ensure that the signs operation (see are not removed nor their legibility impaired by external influences. Death, serious bodily injury and substantial material damage to equipment may occur if the appro priate safety measures are not carried out or the warnings in the text are not observed. Using according to the terms The EMC filters may be used only for their intended application within the specified values in low voltage networks in compliance with the instructions given in the data sheets and the data book. The conditions at the place of application must comply with all specifications for the filter used. Warnings
It shall be ensured that only qualified persons (electricity specialists) are engaged on work such

as planning, assembly, installation, operation, repair and maintenance. They must be provided with the corresponding documentation. Danger of electric shock. EMC filters contain components that store an electric charge. Danger ous voltages can continue to exist at the filter terminals for longer than five minutes even after the power has been switched off. The protective earth connections shall be the first to be made when the EMC filter is installed and the last to be disconnected. Depending on the magnitude of the leakage currents, the particular specifications for making the protective-earth connection must be observed. Impermissible overloading of the EMC filter, such as impermissible voltages at higher frequen cies that may cause resonances etc. can lead to destruction of the filter housing. EMC filters must be protected in the application against impermissible exceeding of the rated currents by suitable overcurrent protective.
8
01/06
EMC filters Important notes
The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of passive electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of a passive electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of a passive electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as "hazardous"). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the "General Terms of Delivery for Products and Services in the Electrical Industry" published by the German Electrical and Electronics Industry Association (ZVEI). 7. The trade names EPCOS, EPCOS-Jones, Baoke, CeraDiode, CSSP, MLSC, PhaseCap, PhaseMod, SIFI, SIKOREL, SilverCap, SIMID, SIOV, SIP5D, SIP5K, UltraCap, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks.
9
01/06


▲Up To Search▲   

 
Price & Availability of B84142A0250S002

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X